LSM2-T-30-D12-C Datasheet, PDF (10/12 Pages) Murata Manufacturing Co., Ltd. – DOSA-SMT, 30A POL DC/DC Converters
PERFORMANCE DATA: OUTPUT VOLTAGE = 1.8 VOLTS
Efficiency vs. Line Voltage and Load Current @ +25°C
91
86
81
VIN = 14 V
76
VIN = 12 V
VIN = 6 V
71
66
61
56
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30
Load Current (Amps)
LSM2-T/30-D12R Maximum Current Temperature Derating at Sea Level
(VIN= 12V, Transverse Airflow). Extra ground pads installed.
31.00
30.00
29.00
28.00
300 LFM
400 LFM
27.00
26.00
25.00
24.00
23.00
Natural Convection
100 LFM
200 LFM
22.00
21.00
20.00
19.00
18.00
17.00
20 25 30 35 40 45 50 55 60 65 70 75 80 85 90
Ambient Temperature (°C)
LSM2-T/30-D12 Maximum Current Temperature Derating at Sea Level
(VIN= 12V, Transverse Airflow). No extra ground pads.
31.00
30.00
29.00
300 LFM
400 LFM
28.00
27.00
26.00
25.00
24.00
23.00
22.00
21.00
20.00 Natural Convection
19.00
100 LFM
18.00
200 LFM
17.00
16.00
15.00
14.00
13.00
20 25 30 35 40 45 50 55 60 65 70 75 80 85 90
Ambie nt Te mpe rature (°C)
www.murata-ps.com/support
LSM2-T/30-D12 Series
DOSA-SMT, 30A POL DC/DC Converters
Output Ripple & Noise (VIN = 12 V, IOUT = 20 A,
COUT = 10μF || 1μF, ’scope = 20 MHz BW)
Vertical = 10 mV/div., Sweep = 1μS/div.
Power-On Startup (VIN = 12 V, IOUT = 25 A)
StepLoad Transient Response (VIN = 12 V, 0-15A-0)