English
Language : 

D1U-W-1600-12-HC2C Datasheet, PDF (2/7 Pages) Murata Power Solutions Inc. – AC/DC Front End Power Supply + S1U Power Shelf
OUTPUT CHARACTERISTICS
Parameter
Remote Sense
Efficiency
Output Rise Monotonicity
Start-up Time
Transient Response
Current sharing accuracy (up to 6 in parallel)
Hot Swap Transients
Hold-up Time
GENERAL CHARACTERISTICS
Parameter
Storage Temperature Range
Operating Temperature Range
Operating Humidity
Storage Humidity
Shock
Sinusoidal Vibration
MTBF
Acoustic
Safety Approvals
Input Fuse
Material Flammability
Switching Frequency
Weight
PROTECTION CHARACTERISTICS
Output
Voltage
Parameter
Over-temperature
Over Voltage
12V
Over Current
3.3Vsb
Over Voltage
Over Current
Over Voltage
5Vsb
Over Current
ISOLATION CHARACTERISTICS
Parameter
Insulation Safety Rating / Test Voltage
Isolation
Material Flammability
Grounding
www.murata-ps.com
D1U-W-1600-12-Hx Series
AC/DC Front End Power Supply + S1U Power Shelf
Conditions
Min.
Typ.
Max.
Units
120
mV
220Vac
90.6
%
Overshoot less than 10% for all outputs, no voltage negative between 10% to 95% during ramp up
AC ramp up
1.5
s
PS_On activated
150
ms
12V Ramp 1A/μs, 50% load step
±600
3.3Vsb Ramp 1A/μs, 50% load step
±165
mV
5Vsb Ramp 1A/μs, 50% load step
±250
At 100% load
±10
%
All outputs within regulation
Max. load, nominal Vin
20
ms
Conditions
Min.
Typ.
Max.
Non-condensing
-40
70
0
50
Non-condensing
10
90
5
90
30G non operating
0.5G, 5 – 500 Hz operating
Calculated per Bellcore at Ta=30°C
200
Demonstrated
200
ISO 7779-1999
60
c-CSA-us (CSA 60950-1-03/UL 60950-1, First Edition)
TUV approval (Bauart) EN 60950-1:2001
Power Supply has internal 20A/250V fast blow fuse on the AC line input
UL 94V-0
90KHz for Boost PFC Converter
165KHz for Main Output Converter
200KHz for Standby Output Converter
2.1kg
Units
°C
%
Khrs
Khrs
dB LpAm
Conditions
Auto-restart
Latching
Latching
Latching
Latching
Latching
Latching
Min.
Typ.
Max.
Units
55
65
°C
13
14
V
145
165
A
3.57
4.02
V
6.5
8
A
5.6
6
V
5
7
A
Conditions
Min.
Typ.
Max.
Units
Input to Output - Reinforced
3000
Vrms
Input to Chassis - Basic
1500
Vrms
Output to Chassis
Output to Output
UL 94V-0
Main Output Return and Standby Output Return are connected internally. 100kΩ resistor parallel with 100nF
capacitor is connected between Return and power supply chassis. Main Output Return should be connected to
the System Chassis.
Technical enquiries email: toronto@murata-ps.com, tel: +1 (866) 740 1232
CPS_D1U-W-1600-12-Hx.C06 Page 2 of 7