English
Language : 

MT9076 Datasheet, PDF (36/160 Pages) Mitel Networks Corporation – T1/E1/J1 3.3V Single Chip Transceiver
MT9076
Preliminary Information
Per Time Slot Control word bit 1 "RPSIG" is set low, CSTi is used to control the transmit channel associated
signaling. The DSTi and DSTo streams contain the transmit and receive voice and digital data.
Only 30 of the 32 ST-BUS channels are used for each of DSTi, DSTo, CSTi and CSTo. In each case individual
channel mapping is as illustrated in Table 10 Time slot to Channel Relationship.
5.0 Reset Operation (Initialization)
The MT9076 can be reset using the hardware RESET pin (pin 11 in PLCC, pin 64 in LQFP) or the software
reset bit RST (page 1H, address 1AH) . When the device emerges from its reset state it will begin to function
with the default settings described in Table 14 (T1) and Table 15 (E1). All control registers are set to 00H. A
reset operation takes 1 full frame (125 us) to complete.
Function
Mode
Loopbacks
SLC-96
Zero Coding
Line Codes
Data Link
signaling
AB/ABCD Bit Debounce
Interrupts
Error Insertion
HDLCs
Counters
Transmit Data
Status
D4
Deactivated
Deactivated
Deactivated
Deactivated
Serial Mode
CAS Registers
Deactivated
masked
Deactivated
Deactivated
Cleared
All Ones
Table 14 - Reset Status(T1)
Function
Mode
Loopbacks
Transmit FAS
Transmit non-FAS
Transmit MFAS (CAS)
Data Link
CRC Interworking
signaling
ABCD Bit Debounce
Interrupts
RxMF Output
Error Insertion
HDLCs
Counters
Transmit Data
Table 15 - Reset Status (E1)
Status
Termination
Deactivated
Cn0011011
1/Sn1111111
00001111
Deactivated
Activated
CAS Registers
Deactivated
Masked
signaling Multiframe
Deactivated
Deactivated
Cleared
All Ones
32