3.5. Recommended Operating Conditions
Functional operation of the device beyond those indicated in the “Recommended Operating Conditions” of this specifi-
cation is not implied, may result in unpredictable behavior of the device and may reduce reliability and lifetime.
All voltages listed are referenced to ground (GND).
Symbol
IO
IO
CL
VDD
B
Parameter
Continuous Output Current
Continuous Output Current
Load Capacitance
Supply Voltage
Magnetic Field Range
Pin No.
2, 3
2, 3
2, 3
1
Min.
Max.
Unit
–2.25
2.25
mA
–1
1
mA
–
1
nF
4.8
12
V
–50
50
mT
Remarks
TJ = 25 °C
TJ = 170 °C
see Fig. 3–2