English
Language : 

HAL300_1 Datasheet, PDF (5/22 Pages) Micronas – Differential Hall Effect Sensor IC
DATA SHEET
1.4. Hall Sensor Package Codes
HAL XXXPA-T
Temperature Range: A or K
Package: SF for SOT89B-2,
UA for TO92UA
Type: 300
Example: HAL300UA-K
→ Type: 300
→ Package: TO92UA
→ Temperature Range: TJ = –40 °C to +140 °C
Hall sensors are available in a wide variety of packaging
versions and quantities. For more detailed information,
please refer to the brochure: “Hall Sensors: Ordering
Codes, Packaging, Handling”.
1.5. Solderability and Welding
Soldering
During soldering reflow processing and manual rework-
ing, a component body temperature of 260 °C should not
be exceeded.
Welding
Device terminals should be compatible with laser and re-
sistance welding. Please note that the success of the
welding process is subject to different welding parame-
ters which will vary according to the welding technique
used. A very close control of the welding parameters is
absolutely necessary in order to reach satisfying results.
Micronas, therefore, does not give any implied or ex-
press warranty as to the ability to weld the component.
1.6. Pin Connections
1VDD
OUT
3
2
GND
Fig. 1–1: Pin configuration
Micronas
HAL300