English
Language : 

HAL300_1 Datasheet, PDF (12/22 Pages) Micronas – Differential Hall Effect Sensor IC
HAL300
DATA SHEET
3.2. Dimensions of Sensitive Area
0.08 mm x 0.17 mm
3.3. Positions of Sensitive Areas (nominal values)
SOT89B-2
TO92UA-3/-4
x1 = −1.025 mm
x2 = 1.025 mm
x1 − x2 = 2.05 mm
y = 0.95 mm
y = 1.0 mm
Bd = 0.2 mm
3.4. Absolute Maximum Ratings
Stresses beyond those listed in the “Absolute Maximum Ratings” may cause permanent damage to the device. This
is a stress rating only. Functional operation of the device at these conditions is not implied. Exposure to absolute maxi-
mum rating conditions for extended periods will affect device reliability.
This device contains circuitry to protect the inputs and outputs against damage due to high static voltages or electric
fields; however, it is advised that normal precautions be taken to avoid application of any voltage higher than absolute
maximum-rated voltages to this high-impedance circuit.
All voltages listed are referenced to ground (GND).
Symbol
Parameter
Pin No.
Limit Values
Unit
Min.
Max.
VDD
Supply Voltage
VO
Output Voltage
1
–15
281)
V
3
–0.3
281)
V
IO
Continuous Output On Current
3
–
30
mA
TJ
Junction Temperature Range
–40
150
°C
–40
1702)
1) as long as TJmax is not exceeded
2) t < 1000h
3.4.1. Storage and Shelf Life
The permissible storage time (shelf life) of the sensors is unlimited, provided the sensors are stored at a maximum of
30 °C and a maximum of 85% relative humidity. At these conditions, no Dry Pack is required.
Solderability is guaranteed for one year from the date code on the package.
12