English
Language : 

HAL856 Datasheet, PDF (33/42 Pages) Micronas – Programmable Linear Hall-Effect Sensor with Arbitrary Output Characteristic (2-Wire)
DATA SHEET
HAL 856
4.6.2. Operation after Reset in Biphase-M Mode with Provide Part Number Option Enabled
VDD
First signal starts
5V
time
OUTPUT
tPOD
Part number max. 100 ms
DATA
No valid signal
Fig. 4–5: Biphase-M after reset
Valid signal
Note: The part number is transmitted twice. The transmission time depends on the chosen bit time, but is a maxi-
mum 100 ms.
Micronas
March 23, 2010; DSH000142_002EN
33