English
Language : 

HAL556_1 Datasheet, PDF (15/26 Pages) Micronas – Two-Wire Hall-Effect Sensor Family
DATA SHEET
HAL55x, HAL56x
3.7. Magnetic Characteristics Overview
at TJ = −40 °C to +140 °C, VDD = 4.0 V to 24 V,
Typical Characteristics for VDD = 12 V
Magnetic flux density values of switching points.
Positive flux density values refer to the magnetic south pole at the branded side of the package.
Sensor
Switching Type
HAL 556
Parameter
TJ
−40 °C
On point BON
Min.
Typ.
Max.
3.4
6.3
7.7
Off point BOFF
Min.
Typ.
Max.
2.1
4.2
5.9
Hysteresis BHYS
Min.
Typ.
Max.
0.8
2.1
3
Unit
mT
unipolar
25 °C 3.4
6
7.4
2
3.8
5.7
0.5
1.8
2.8
mT
100 °C 3.2
5.5
7.2
1.9
3.7
5.7
0.3
1.8
2.8
mT
140 °C 3
5.2
7.4
1.2
3.6
6
0.2
1.6
3
mT
HAL 560
−40 °C 41
46.5
52
47
53
59
4
6.5
10
mT
unipolar
25 °C 41
46.6
52
46
52.5
58.5
3
6
9
mT
inverted
100 °C 41
45.7
52
45
41.1
57.5
2
5.4
8
mT
140 °C 39
44.8
51
43.5
49.8
56.5
2
5
8
mT
HAL 566
−40 °C 2.1
4
5.9
3.4
6
7.7
0.8
2
2.8
mT
unipolar
25 °C 2
3.9
5.7
3.4
5.9
7.2
0.5
2
2.7
mT
inverted
100 °C 1.85
3.8
5.7
3.25
5.6
7
0.3
1.8
2.6
mT
140 °C 1.3
3.6
7.3
2.6
5.2
7.3
0.2
1.6
3
mT
Note: For detailed descriptions of the individual types, see pages 18 and following.
Micronas
Aug. 11, 2009; DSH000026_004EN
15