Figure 39: Word Program Full Status Check Procedure
Read status
register
SR3 =
1
0
VPPerrraonrge
SR4 =
1
0
Program
error
SR1 =
1
0
Device protect
error
Program
successful
Note:
SR3 MUST be cleared before the write state machine will support further program attempts.
Bus
Operation Command Comments
Idle
None
Check SR3
1 = VPP error
Idle
None
Check SR4
1 = Data program error
Idle
None
Check SR1
1 = Block locked; operation aborted
Note: 2. If an error is detected, clear the status register before continuing operations. Only the
CLEAR STAUS REGISTER command clears the status register error bits.