English
Language : 

PIC24FJ256GA110 Datasheet, PDF (17/22 Pages) Microchip Technology – 64/80/100-Pin, 16-Bit General Purpose Flash Microcontrollers with Peripheral Pin Select
PIC24FJ256GA110 FAMILY
7. Module: Electrical Specifications
In Section 28.0 “Electrical Characteristics”,
Table 28-13 (External Clock Timing Requirements)
has been replaced with Table 4 below:
TABLE 4: EXTERNAL CLOCK TIMING REQUIREMENTS
AC CHARACTERISTICS
Standard Operating Conditions: 2.50 to 3.6V (unless otherwise stated)
Operating temperature -40°C  TA  +85°C for Industrial
-40°C  TA  +125°C for Extended
Param
No.
Sym
Characteristic
Min
Typ(1) Max Units
Conditions
OS10 FOSC External CLKI Frequency
DC
(External clocks allowed 
4
only in EC mode)
DC
4
—
32
MHz EC, -40°C  TA  +85°C
—
8
MHz ECPLL, -40°C  TA  +85°C
—
24
MHz EC, -40°C  TA  +125°C
—
6
MHz ECPLL, -40°C  TA  +125°C
Oscillator Frequency
3
—
10
MHz XT
3
—
8
MHz XTPLL, -40°C  TA  +85°C
10
—
32
MHz HS, -40°C  TA  +85°C
31
—
33
kHz SOSC
3
—
6
MHz XTPLL, -40°C  TA  +125°C
10
—
24
MHz HS, -40°C  TA  +125°C
OS20 TOSC TOSC = 1/FOSC
OS25 TCY Instruction Cycle Time(2)
—
62.5
—
—
—
DC
— See Parameter OS10
for FOSC value
ns
OS30 TosL, External Clock in (OSCI) 0.45 x TOSC —
—
TosH High or Low Time
ns EC
OS31 TosR, External Clock in (OSCI)
—
TosF Rise or Fall Time
OS40 TckR CLKO Rise Time(3)
—
OS41 TckF CLKO Fall Time(3)
—
—
20
6
10
6
10
ns EC
ns
ns
Note 1: Data in “Typ” column is at 3.3V, 25°C unless otherwise stated. Parameters are for design guidance only
and are not tested.
2: Instruction cycle period (TCY) equals two times the input oscillator time base period. All specified values
are based on characterization data for that particular oscillator type under standard operating conditions
with the device executing code. Exceeding these specified limits may result in an unstable oscillator
operation and/or higher than expected current consumption. All devices are tested to operate at “Min.”
values with an external clock applied to the OSCI/CLKI pin. When an external clock input is used, the
“Max.” cycle time limit is “DC” (no clock) for all devices.
3: Measurements are taken in EC mode. The CLKO signal is measured on the OSCO pin. CLKO is low for
the Q1-Q2 period (1/2 TCY) and high for the Q3-Q4 period (1/2 TCY).
 2008-2013 Microchip Technology Inc.
DS80368N-page 17