TABLE 6-3: PROGRAMMING/VERIFY TIMING REQUIREMENTS
VDD = 5.0V ± 10%
25° C ± 5 ° C
Parameter
Symbol
Min.
Program mode setup time
T2
0
Hold time 1
T1
9.0
Program cycle time
TWC
50
Clock low time
TCLKL
50
Clock high time
TCLKH
50
Data setup time
TDS
0
Data hold time
TDH
30
Data out valid time
TDV
—
Note 1: Typical values - not tested in production.
Max.
4.0
—
—
—
—
—
—
30
HCS361
Units
ms
ms
ms
μs
μs
μs(1)
μs(1)
μs(1)