REGISTER 15-1: OCxCON1: OUTPUT COMPARE x CONTROL REGISTER 1
U-0
—
bit 15
U-0
R/W-0
R/W-0
R/W-0
R/W-0
R/W-0
—
OCSIDL OCTSEL2 OCTSEL1 OCTSEL0 ENFLT2
R/W-0
ENFLT1
bit 8
R/W-0
ENFLT0
bit 7
R/W-0, HCS R/W-0, HCS R/W-0, HCS R/W-0
OCFLT2
OCFLT1
OCFLT0 TRIGMODE
R/W-0
OCM2(1)
R/W-0
OCM1(1)
R/W-0
OCM0(1)
bit 0
Legend:
R = Readable bit
-n = Value at POR
HCS = Hardware Clearable/Settable bit
W = Writable bit
U = Unimplemented bit, read as ‘0’
‘1’ = Bit is set
‘0’ = Bit is cleared
x = Bit is unknown
bit 15-14
bit 13
bit 12-10
bit 9
bit 8
bit 7
bit 6
bit 5
bit 4
bit 3
Unimplemented: Read as ‘0’
OCSIDL: Stop Output Compare x in Idle Mode Control bit
1 = Output compare x halts in CPU Idle mode
0 = Output compare x continues to operate in CPU Idle mode
OCTSEL<2:0>: Output Compare x Timer Select bits
111 = System clock
110 = Reserved
101 = Reserved
100 = Timer1
011 = Timer5
010 = Timer4
001 = Timer3
000 = Timer2
ENFLT2: Comparator Fault Input Enable bit(2)
1 = Comparator Fault input is enabled
0 = Comparator Fault input is disabled
ENFLT1: OCFB Fault Input Enable bit
1 = OCFB Fault input is enabled
0 = OCFB Fault input is disabled
ENFLT0: OCFA Fault Input Enable bit
1 = OCFA Fault input is enabled
0 = OCFA Fault input is disabled
OCFLT2: PWM Comparator Fault Condition Status bit(2)
1 = PWM comparator Fault condition has occurred (this is cleared in hardware only)
0 = PWM comparator Fault condition has not occurred (this bit is used only when OCM<2:0> = 111)
OCFLT1: PWM OCFB Fault Input Enable bit
1 = PWM OCFB Fault condition has occurred (this is cleared in hardware only)
0 = PWM OCFB Fault condition has not occurred (this bit is used only when OCM<2:0> = 111)
OCFLT0: PWM OCFA Fault Condition Status bit
1 = PWM OCFA Fault condition has occurred (this is cleared in hardware only)
0 = PWM OCFA Fault condition has not occurred (this bit is used only when OCM<2:0> = 111)
TRIGMODE: Trigger Status Mode Select bit
1 = TRIGSTAT (OCxCON2<6>) is cleared when OCxRS = OCxTMR or in software
0 = TRIGSTAT is only cleared by software
Note 1: The comparator module used for Fault input varies with the OCx module. OC1 and OC2 use
Comparator 1; OC3 and OC4 use Comparator 2; OC5 uses Comparator 3.
 2011 Microchip Technology Inc.
DS39995B-page 161