10. Pressure Accuracy Specifications
DC Operating Parameters T = -40°C to 150°C, VDD = 5V (unless otherwise specified)
Parameter
Non Linearity Error(9)
Hysteresis
Symbol
Test Conditions
EBA
Room Temperature
10 bar (2 point calibration)
35 bar (2 point calibration)
EBB
Room Temperature
30 bar (2 point calibration)
50 bar (2 point calibration)
Min Max Units
0.1
0.2
%FSO
0.1
0.2
%FSO
-0.25 0.25 %FSO
Programmable Pressure
Spans
Overall Accuracy(10)
EBA
EBB
10
35
Bar
30
50
-2.5 2.5 %FSO
Table 6: Pressure accuracy specification
11. Application Information
The MLX90819 only needs 2 capacitors in the application, a 47nF decoupling capacitor on the supply line and a 47nF load on
the analog output pin. When the SENT output is used a 2.2nF capacitor is recommended. Consult Melexis to discuss the ideal
application schematics depending on the EMC specs to be fulfilled.
MLX90819 in analog mode
Vdd
47nF
47nF
Gnd
AnaOut
Figure 4: MLX90819 application schematic - analog
9 Best Fit Non Linearity using ceramics prototype package.
10 Indicative overall accuracy using ceramics prototype package and calibration in engineering setup of EBA at 20bar and EBB at 50bar.