9. General Electrical Specifications
DC Operating Parameters T = -40°C to 150°C, VDD = 5V (unless otherwise specified)
Parameter
Nominal Supply Voltage
Nominal Supply Current
Load Resistance
Capacitive Load
Diagnostic Limits
Clamping Levels(5)
Analog Saturation Output
Level
Power Up Time(6)
Response Time(7)
Ratiometricity Error
Analog Output noise(8)
SENT Output noise(8)
Symbol
Test Conditions
Min Typ(4) Max
VDD
4.5
5
5.5
IDD
No output load connected
7
8
RLOAD
Pull-up or Pull-down
4.7
CLOAD
2.2
470
diag_lo
Pull-up ≥ 4.7kΩ
2
diag_hi
Pull-up ≥ 4.7kΩ
96
Pull-up ≥ 10kΩ
98
clamp_lo
0
25
clamp_hi
50
100
Units
V
mA
kΩ
nF
%VDD
%VDD
%VDD
%VDD
vsat_lo
vsat_hi
Depending on the load
0
configuration
97
2
%VDD
100
%VDD
5.5
ms
1
ms
0.2
%VDD
2 mVrms
1.8 LSBrms
Table 5: General electrical specification
4Typical values are defined at TA = +25ºC and VDD = 5V
5 Programmable range with 8 bits resolution for the low clamping level and 9 bits resolution for the high clamping level (See application note 90819
Advanced Configuration Settings for detailed information)
6 Time from reaching the minimum allowed supply voltage of 4.5V till having the output within specification
7 Time needed for the output to react to a pressure change from 10% to 90% of its final value (pressure change corresponding to maximum a 4V
output change) using default filter settings SSF=1, PFLT = 0 (See application note 90819 Advanced Configuration Settings for detailed inform ation)
8 Bandwidth limited to 50kHz. Using default filter settings SSF = 1, PFLT = 0.
REVISION 3 – OCTOBER 20, 2016
3901090819
Page 7 of 11