MLX90614_15 Datasheet, PDF (7/51 Pages) Melexis Microelectronic Systems – Single and Dual Zone Infra Red Thermometer in TO-39
Parameter
Symbol
MLX90614 family
Single and Dual Zone
Infra Red Thermometer in TO-39
Test Conditions
Min
Typ
Max Units
Input high voltage
Input low voltage
SMBus compatible 2-wire interface2
VIH (Ta, V) Over temperature and supply
3
VIL (Ta, V)
Over temperature and supply
Output low voltage
VOL
Over temperature and supply,
Isink = 2mA
SCL leakage
ISCL, leak
VSCL=4V, Ta=+85°C
SDA leakage
ISDA, leak
VSDA=4V, Ta=+85°C
SCL capacitance
CSCL
SDA capacitance
CSDA
Slave address
SA
Factory default
5A
Wake up request
twake
SDA low
33
SMBus Request
tREQ
SCL low
1.44
Timeout, low
Timeout,L
SCL low
27
Timeout, high
Timeout,H
SCL high
45
Acknowledge setup time Tsuac(MD) 8-th SCL falling edge, Master
Acknowledge hold time Thdac(MD) 9-th SCL falling edge, Master
Acknowledge setup time Tsuac(SD)
8-th SCL falling edge, Slave
Acknowledge hold time Thdac(SD) 9-th SCL falling edge, Slave
EEPROM
Data retention
Ta = +85°C
10
Erase/write cycles
Ta = +25°C
100,000
Erase/write cycles
Ta = +125°C
10,000
Erase cell time
Terase
5
Write cell time
Twrite
5
Table 3: Electrical specification MLX90614Axx
V
0.6
V
0.2
V
30
µA
0.3
µA
10
pF
10
pF
hex
ms
ms
33
ms
55
µs
1.5
µs
1.5
µs
2.5
µs
1.5
µs
years
Times
Times
ms
ms
Notes: All the communication and refresh rate timings are given for the nominal calibrated HFO frequency and
will vary with this frequency’s variations.
1. With large capacitive load lower PWM frequency is recommended. Thermal relay output (when
configured) has the PWM DC specification and can be programmed as push-pull, or NMOS open drain. PWM is
free-running, power-up factory default is SMBus, refer to section 8.6, “Switching between PWM and SMBus
communication” for more details.
2. For SMBus compatible interface on 12V application refer to Application information section. SMBus
compatible interface is described in details in the SMBus detailed description section. Maximum number of
MLX90614 devices on one bus is 127, higher pull-up currents are recommended for higher number of devices,
faster bus data transfer rates, and increased reactive loading of the bus.
MLX90614 is always a slave device on the bus. MLX90614 can work in both low-power and high-power SMBus
communication.
All voltages are referred to the Vss (ground) unless otherwise noted.
Sleep mode is not available on the 5V version (MLX90614Axx).
3901090614
Rev 009
Page 7 of 52
Data Sheet
June 29, 2015