MLX90614 family
Single and Dual Zone
Infra Red Thermometer in TO-39
The TRAM is the linearized Tobj, 16-bit (0x0000…0xFFFF, 0x0000 for -273.15°C and 0xFFFF for
+382.2°C) and the result is a 10-bit word, in which 0x000 corresponds to ToMIN[°C], 0x3FF corresponds to
ToMAX[°C]
and
1LSB
corresponds
to
ToMAX − ToMIN
1023
[°C].
TMIN EEPORM = TMIN ×100 LSB
TMAX EEPORM = TMAX ×100 LSB
The ambient data for PWM is rescaled according to the following equation:
T = T K− T PWM ambient
RAM
MIN EEPROM
PWM ambient
Where:
K = T 10−23T PWM ambient
MAX EEPROM
MIN EEPROM
The result is a 10-bit word, where 0x000 corresponds to -38.2°C (lowest Ta that can be read via PWM),
0x3FF corresponds to 125°C (highest Ta that can be read via PWM) and 1LSB corresponds to:
[ ] 1LSB = TMAX − TMIN , °C
1023
( ( )) TMINEEPORM = TMIN − − 38.2
× 100 LSB
64
( ( )) TMAX EEPORM = TMAX − − 38.2
× 100 LSB
64