Features and Benefits
Small size, low cost
Easy to integrate
Factory calibrated in wide temperature range:
-40…+125˚C for sensor temperature and
-70…+380˚C for object temperature.
High accuracy of 0.5°C in a wide temperature
range (0…+50°C for both Ta and To)
High (medical) accuracy calibration
Measurement resolution of 0.02°C
Single and dual zone versions
SMBus compatible digital interface
Customizable PWM output for continuous
reading
Available in 3V and 5V versions
Simple adaptation for 8…16V applications
Sleep mode for reduced power consumption
Different package options for applications and
measurements versatility
Automotive grade
Applications Examples
High precision non-contact temperature
measurements
Thermal Comfort sensor for Mobile Air
Conditioning control system
Temperature sensing element for residential,
commercial and industrial building air
conditioning
Windshield defogging
Automotive blind angle detection
Industrial temperature control of moving parts
Temperature control in printers and copiers
Home appliances with temperature control
Healthcare
Livestock monitoring
Movement detection
Multiple zone temperature control – up to 127
sensors can be read via common 2 wires
Thermal relay / alert
Body temperature measurement
Ordering Information
Part No.
Temperature
Code
Package - Option Code Standard Packing
Code
-X X X
part
form
MLX90614 E (-40°C...85°C) SF (TO-39)
(1) (2) (3)
-000
-TU
K (-40°C…125°C)
(1) Supply Voltage/ Accuracy
A - 5V
B - 3V
(2) Number of thermopiles:
A – single zone
B – dual zone
(3) Package options:
A – Standard package
B – Reserved
C - Reserved
D - 3V medical accuracy
C – gradient compensated*
C – 35° FOV
D/E – Reserved
F – 10° FOV
G – Reserved
H – 12° FOV (refractive lens)
I – 5° FOV
Example:
MLX90614ESF-BAA-000-TU * : See page 2
1 Functional diagram
MLX90614Axx: Vdd=4.5...5.5V
J1
1 MLX90614
SCL
SCL
U1
Vz
SDA
PWM
2 SDA
Vss 4
Vdd
GND
Vdd C1
3
CON1
0.1uF
C1 value and type may differ
in different applications
for optimum EMC
MLX90614 connection to SMBus
Figure 1: Typical application schematics
2 General Description
The MLX90614 is an Infra Red thermometer for non
contact temperature measurements. Both the IR sensitive
thermopile detector chip and the signal conditioning ASSP
are integrated in the same TO-39 can.
Thanks to its low noise amplifier, 17-bit ADC and
powerful DSP unit, a high accuracy and resolution of the
thermometer is achieved.
The thermometer comes factory calibrated with a digital
PWM and SMBus (System Management Bus) output.
As a standard, the 10-bit PWM is configured to
continuously transmit the measured temperature in range
of -20…120˚C, with an output resolution of 0.14˚C.
The factory default POR setting is SMBus.
3901090614