MLX90614_15 Datasheet, PDF (29/51 Pages) Melexis Microelectronic Systems – Single and Dual Zone Infra Red Thermometer in TO-39
Initialization
TA Offset meas
OSTa= meas(NTos)
filtering
TOS= IIR(LTos,OSTa)
TA meas
TDATA= meas(NTa)
Offset comp
TDATAcomp= TDATA-TOS
filtering
TD= IIR(LTa,TDATAcomp)
TA calculation
1
MLX90614 family
Single and Dual Zone
Infra Red Thermometer in TO-39
1
IR Offset meas
OSIR= meas(NIRos)
filtering
IROS= IIR(LIRos,OSIR)
Gain drift
IRGm= meas(NIRg)
Offset comp
IRGcomp= IRGm- IROS
filtering
IRG= IIR(LG,IRGcomp)
KG calculation
2
IR1 meas
IR1D= meas(NIR)
Offset comp
IR1Dcomp= IR1D- IROS
Gain comp
IR1Dg= IR1Dcomp*KG
filtering
IR1D= IIR(LIR,IR1Dg)
TOBJ1 calculation
3
IR2 meas
IR2D= meas(NIR)
Offset comp
IR2Dcomp= IR2D- IROS
Gain comp
IR2Dg= IR2Dcomp*KG
filtering
IR2D= IIR(LIR,IR2Dg)
TOBJ2 calculation
PWM calculation
2
3
Figure 20: Software flow
Load PWM registers
3901090614
Rev 009
Page 29 of 52
Data Sheet
June 29, 2015