English
Language : 

MLX92211 Datasheet, PDF (5/13 Pages) Melexis Microelectronic Systems – 3-Wire Hall Effect Latch
MLX92211-AxA
3-Wire Hall Effect Latch
6 Magnetic Specifications
6.1 MLX92211LSE-AAA-000
DC Operating Parameters VDD = 3.8 to 24V, Ta = -40°C to 150°C
Test Condition
Operating Point
BOP (mT)
Min
Typ(1)
Max
Release Point
BRP (mT)
Min
Typ(10)
Max
TJ = -40°C
TJ = 25°C
TJ = 150°C
1.4
3.2
4.7 -4.7 -3.2 -1.4
1.4
3
4.7 -4.7 -3.0 -1.4
0.7
2.6
5
-5
-2.6 -0.7
6.2 MLX92211LUA-AAA-000
DC Operating Parameters VDD = 3.8 to 24V, Ta = -40°C to 150°C
Test Condition
TJ = -40°C
TJ = 25°C
TJ = 150°C
Operating Point
BOP (mT)
Min
Typ(1)
Max
1.4
3.2
4.7
1.4
3
4.7
0.7
2.6
5
Release Point
BRP (mT)
Min
Typ(10)
Max
-4.7 -3.2 -1.4
-4.7 -3.0 -1.4
-5
-2.6 -0.7
6.3 MLX92211LSE-ACA-000
DC Operating Parameters VDD = 3.8 to 24V, Ta = -40°C to 150°C
Test Condition
TJ = -40°C
TJ = 25°C
TJ = 150°C
Operating Point
BOP (mT)
Min
Typ(1)
Max
1.2
3.2
5.5
1.0
2.8
4.7
0.5
2.1
4.2
Release Point
BRP (mT)
Min
Typ(10)
Max
-5.5 -3.2 -1.2
-4.7 -2.8 -1.0
-4.2 -2.1 -0.5
6.4 MLX92211LSE-ADA-000
DC Operating Parameters VDD = 3.8 to 24V, Ta = -40°C to 150°C
Test Condition
TJ = -40°C
TJ = 25°C
TJ = 150°C
Operating Point
BOP (mT)
Min
Typ(1)
Max
11.0 15.1 20.0
10.2 13.5 17.1
6.7 10.3 14.7
Release Point
BRP (mT)
Min
Typ(10)
Max
-20.0 -15.1 -11.0
-17.1 -13.5 -10.2
-14.7 -10.3 -6.7
TC
(ppm/oC)
Typ(1)
-1100
TC
(ppm/oC)
Typ(1)
-1100
TC
(ppm/oC)
Typ(1)
-2000
TC
(ppm/oC)
Typ(1)
-2000
Active Pole
South Pole
Active Pole
South Pole
Active Pole
North Pole
Active Pole
South Pole
1 Typical values are defined at TA = +25°C and VDD = 12V, unless otherwise specified
390109221101
Rev. 007
Page 5 of 13
www.melexis.com
Datasheet
Jan/15