1: The WCOL bit is set if the SPI data register, SPDAT, is written during a data transfer (see Section 15.2.4:
Write Collision).
Bit 5~0: Reserved.
SPDAT: SPI Data Register
SFR Page
= All
SFR Address = 0x86
7
6
5
(MSB)
R/W
R/W
R/W
RESET= 0000-0000
4
3
2
R/W
R/W
R/W
1
0
(LSB)
R/W
R/W
SPDAT has two physical buffers for writing to and reading from during transmit and receive, respectively.