English
Language : 

MAX16060 Datasheet, PDF (9/18 Pages) Maxim Integrated Products – 1% Accurate, Quad-/Hex-/Octal-Voltage uP Supervisors
1% Accurate, Quad-/Hex-/Octal-Voltage
µP Supervisors
Pin Description (MAX16062)
PIN NAME
FUNCTION
1
IN5 Monitored Input Voltage 5. See Table 1 for the input voltage threshold.
2
IN6 Monitored Input Voltage 6. See Table 1 for the input voltage threshold.
3
IN7 Monitored Input Voltage 7. See Table 1 for the input voltage threshold.
4
IN8 Monitored Input Voltage 8. See Table 1 for the input voltage threshold.
Watchdog Timer Input. If WDI remains low or high for longer than the watchdog timeout period, RESET is
asserted and the timer is cleared. The timer also clears whenever a reset is asserted or a rising or falling edge on
5
WDI
WDI is detected. The watchdog timer enters a startup period that allows 54s for the first transition to occur before
a reset. Leave WDI unconnected to disable the watchdog timer. The WDI unconnected state detector uses a
small 400nA current. Therefore, do not connect WDI to anything that will source or sink more than 200nA. Note
that the leakage current specification for most three-state drivers exceeds 200nA.
6
GND Ground
7
VCC Unmonitored Power-Supply Input
8
OUT5
Output 5. When the voltage at IN5 falls below its threshold, OUT5 goes low and stays low until the voltage at IN5
exceeds its threshold. The open-drain output has a 30µA internal pullup to VCC.
9
OUT6 Output 6. When the voltage at IN6 falls below its threshold, OUT6 goes low and stays low until the voltage at IN6
exceeds its threshold. The open-drain output has a 30µA internal pullup to VCC.
10
OUT7 Output 7. When the voltage at IN7 falls below its threshold, OUT7 goes low and stays low until the voltage at IN7
exceeds its threshold. The open-drain output has a 30µA internal pullup to VCC.
11
OUT8 Output 8. When the voltage at IN8 falls below its threshold, OUT8 goes low and stays low until the voltage at IN8
exceeds its threshold. The open-drain output has a 30µA internal pullup to VCC.
12
MR
Active-Low Manual Reset Input. Pull MR low to assert RESET low. RESET remains low for the reset timeout period
after MR is deasserted. MR is pulled up to VCC through a 20kΩ resistor.
Set Reset Timeout Input. Connect a capacitor from SRT to GND to set the reset timeout period. The reset timeout
13
SRT period can be calculated as follows:
Reset Timeout (s) = 2.06 x 106 (Ω) x CSRT (F). For the internal timeout period of 140ms (min), connect SRT to VCC.
14
MARGIN Margin Disable Input. Pull MARGIN low to deassert all outputs (go into high state), regardless of the voltage at
any monitored input.
15
OUT4
Output 4. When the voltage at IN4 falls below its threshold, OUT4 goes low and stays low until the voltage at IN4
exceeds its threshold. The open-drain output has a 30µA internal pullup to VCC.
16
OUT3
Output 3. When the voltage at IN3 falls below its threshold, OUT3 goes low and stays low until the voltage at IN3
exceeds its threshold. The open-drain output has a 30µA internal pullup to VCC.
17
OUT2 Output 2. When the voltage at IN2 falls below its threshold, OUT2 goes low and stays low until the voltage at IN2
exceeds its threshold. The open-drain output has a 30µA internal pullup to VCC.
18
OUT1 Output 1. When the voltage at IN1 falls below its threshold, OUT1 goes low and stays low until the voltage at IN1
exceeds its threshold. The open-drain output has a 30µA internal pullup to VCC.
Active-Low Reset Output. RESET asserts low when any of the monitored voltages falls below its respective
19 RESET threshold or MR is asserted. RESET remains asserted for the reset timeout period after all monitored voltages
exceed their respective thresholds and MR is deasserted. This open-drain output has a 30µA internal pullup.
20
IN1 Monitored Input Voltage 1. See Table 1 for the input voltage threshold.
21
IN2 Monitored Input Voltage 2. See Table 1 for the input voltage threshold.
22
IN3 Monitored Input Voltage 3. See Table 1 for the input voltage threshold.
23
IN4 Monitored Input Voltage 4. See Table 1 for the input voltage threshold.
24
TOL Threshold Tolerance Input. Connect TOL to GND to select 5% threshold tolerance. Connect TOL to VCC to select
10% threshold tolerance.
—
EP
Exposed Pad. EP is internally connected to GND. Connect EP to the ground plane to provide a low thermal resistance
path from the IC junction to the PCB. Do not use as the electrical connection to GND.
_______________________________________________________________________________________ 9