English
Language : 

MAX16060 Datasheet, PDF (17/18 Pages) Maxim Integrated Products – 1% Accurate, Quad-/Hex-/Octal-Voltage uP Supervisors
1% Accurate, Quad-/Hex-/Octal-Voltage
µP Supervisors
Margin Output Disable (MARGIN)
MARGIN allows system-level testing while power sup-
plies are adjusted from their nominal voltages. Drive
MARGIN low to force RESET and OUT_ high, regard-
less of the voltage at any monitored input. The state of
each output does not change while MARGIN = GND.
The watchdog timer continues to run when
MARGIN is low, and if a timeout occurs, RESET will
assert tMD after MARGIN is deasserted.
The MARGIN input is internally pulled up to VCC. Leave
MARGIN unconnected or connect to VCC if unused.
Undervoltage Lockout (UVLO)
The MAX16060/MAX16061/MAX16062 feature a VCC
undervoltage lockout (UVLO) that preserves a reset
status even if VCC falls as low as 1V. The undervoltage
lockout circuitry monitors the voltage at VCC. If VCC
falls below the UVLO falling threshold (typically
1.735V), RESET is asserted and all OUT_ are asserted
low. This eliminates an incorrect RESET or OUT_ output
state as VCC drops below the normal VCC operational
voltage range of 1.98V to 5.5V.
During power-up as VCC rises above 1V, RESET is
asserted and all OUT_ are asserted low until VCC
exceeds the UVLO threshold. As VCC exceeds the UVLO
threshold, all inputs are monitored and the correct output
state appears at all the outputs. This also ensures that
RESET and all OUT_ are in the correct state once VCC
reaches the normal VCC operational range.
Power-Supply Bypassing
In noisy applications, bypass VCC to ground with a
0.1µF capacitor as close to the device as possible. The
additional capacitor improves transient immunity. For
fast-rising VCC transients, additional capacitance may
be required.
______________________________________________________________________________________ 17