English
Language : 

MAX14824 Datasheet, PDF (7/28 Pages) Maxim Integrated Products – IO-Link Master Transceiver
MAX14824
IO-Link Master Transceiver
AC ELECTRICAL CHARACTERISTICS (continued)
(VCC = 18V to 36V, VL = 2.3V to 5.5V, VGND = 0V; all logic inputs at VL or GND; TA = -40oC to +105oC, unless otherwise noted. Typical
values are at VCC = 24V, VL = 3.3V, and TA = +25oC, unless otherwise noted.) (Note 2)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
SDI Setup Time
Output Data Propagation Delay
SDO Rise and Fall Times
Minimum CS Pulse
tDS
tDO
tFT
tCSW
10
ns
32
ns
20
ns
76.8
ns
Note 2: All devices are 100% production tested at TA = +25NC. Limits over the operating temperature range are guaranteed by
design.
Note 3: UV is an open-drain output. Connect UV to a voltage less than 5.5V through an external pullup resistor.
Note 4: Disable time measurements are load-dependent.
Note 5: Guaranteed by design. Limits are not production tested.
  7