English
Language : 

DS12CR885 Datasheet, PDF (7/22 Pages) Maxim Integrated Products – RTC with Constant-Voltage Trickle Charger
RTC with Constant-Voltage Trickle Charger
POWER-UP/POWER-DOWN CHARACTERISTICS
(TA = -40°C to +85°C) (Note 1)
PARAMETER
Recovery at Power-Up
VCC Fall Time; VPF(MAX) to
VPF(MIN)
SYMBOL
tRPU
tF
CONDITIONS
VCC Rise Time; VPF(MIN) to
VPF(MAX)
tR
CAPACITANCE
(TA = +25°C)
PARAMETER
Capacitance on All Input Pins
Except X1 and X2
Capacitance on IRQ, SQW, and
DQ Pins
SYMBOL
CIN
(Note 9)
CIO
(Note 9)
CONDITIONS
MIN TYP MAX UNITS
20
200
ms
300
µs
0
µs
MIN TYP MAX UNITS
10
pF
10
pF
AC TEST CONDITIONS
PARAMETER
Input Pulse Levels (-5)
Input Pulse Levels (-33)
Output Load Including Scope and Jig (-5)
Output Load Including Scope and Jig (-33)
Input and Output Timing Measurement Reference Levels
Input-Pulse Rise and Fall Times
TEST CONDITIONS
0 to 3.0V
0 to 2.7V
50pF + 1TTL Gate
25pF + 1TTL Gate
Input/Output: VIL maximum and VIH minimum
5ns
WARNING: Negative undershoots below -0.3V while the part is in battery-backed mode may cause loss of data.
Note 1:
Note 2:
Note 3:
Note 4:
Note 5:
Note 6:
Note 7:
Note 8:
Note 9:
Limits at -40°C are guaranteed by design and not production tested.
All voltages are referenced to ground.
All outputs are open.
Specified with CS = DS = R/W = RESET = VCC; MOT, AS, AD0–AD7 = 0; VBACKUP open.
Applies to the AD0 to AD7 pins, the IRQ pin, and the SQW pin when each is in a high-impedance state.
The MOT pin has an internal 20kΩ pulldown.
Measured with a 32.768kHz crystal attached to X1 and X2.
Measured with a 50pF capacitance load.
Guaranteed by design. Not production tested.
_____________________________________________________________________ 7