English
Language : 

MAX15014_07 Datasheet, PDF (6/26 Pages) Maxim Integrated Products – 1A, 4.5V to 40V Input Buck Converters with 50mA Auxiliary LDO Regulators
1A, 4.5V to 40V Input Buck Converters with
50mA Auxiliary LDO Regulators
ELECTRICAL CHARACTERISTICS (continued)
(VIN_SW = VIN_LDO = VDRAIN = 14V, VEN_SYS = VEN_SW = 2.4V, VREG = VDVREG, VSYNC = VSET_LDO = VSGND = VPGND = 0V, CREG =
1µF, CIN_SW = 0.1µF, CIN_LDO = 0.1µF, CLDO_OUT = 10µF, CDRAIN = 0.22µF, TA = TJ = -40°C to +125°C, unless otherwise noted.
Typical values are at TA = +25°C.) (Note 1)
PARAMETER
RESET OUTPUT
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
RESET Threshold
RESET Output Low Voltage
RESET Output High Leakage
Current
V RESET
VRL
IRH
RESET goes high after rising VLDO_OUT
crosses this threshold
(VLDO_OUT – VRESET) / IRESET = 4kΩ
V RESET = 3.3V (For MAX15_ _ _B),
V RESET = 5V (For MAX15_ _ _A)
90
92.5
95 %VOUT
0.4
V
1
µA
RESET Output Minimum Timeout
When LDO_OUT reaches RESET threshold,
50
µs
Period
CT = unconnected
ENABLE to RESET Minimum
Timeout Period
When EN_SYS goes high, CLDO_OUT =
10µF, ILDO_OUT = 50mA, VLDO_OUT = 3.3V,
650
µs
CT = unconnected
Delay Comparator Threshold
(Rising)
Delay Comparator Threshold
Hysteresis
CT Charge Current
CT Discharge Current
THERMAL SHUTDOWN
Thermal Shutdown Temperature
Thermal Shutdown Hysteresis
VCT-TH
VCTTH-
HYST
ICT-CHQ
ICT-DIS
VCT = 0V
Temperature rising
1.220 1.241 1.265
V
100
mV
1.5
2
3
µA
18
mA
+160
°C
20
°C
Note 1: Limits at -40°C are guaranteed by design and not production tested.
Note 2: Maximum output current is limited by package power dissipation.
Note 3: This is the minimum voltage needed at SET_LDO for the system to recognize that the user wants an adjustable LDO_OUT.
6 _______________________________________________________________________________________