TIMING CHARACTERISTICS (Figure 1) (continued)
(VDD = 2.7V to 3.6V (MAX11613/MAX11615/MAX11617), VDD = 4.5V to 5.5V (MAX11612/MAX11614/MAX11616), VREF = 2.048V
(MAX11613/MAX11615/MAX11617), VREF = 4.096V (MAX11612/MAX11614/MAX11616), fSCL = 1.7MHz, TA = TMIN to TMAX, unless
otherwise noted. Typical values are at TA = +25°C, see Tables 1–5 for programming notation.)
and for the MAX11612/MAX11614/MAX11616, where N is the number of bits:
[ ] ⎡
⎢ VFS(5.5V) − VFS(4.5V)
⎣⎢
× 2N − 1⎤⎥
VREF ⎦⎥
(5.5V − 4.5V)
Note 10: A master device must provide a data hold time for SDA (referred to VIL of SCL) to bridge the undefined region of SCL’s
falling edge (see Figure 1).
Note 11: The minimum value is specified at TA = +25°C.
Note 12: CB = total capacitance of one bus line in pF.
Note 13: fSCL must meet the minimum clock low time plus the rise/fall times.
Typical Operating Characteristics
(VDD = 3.3V (MAX11613/MAX11615/MAX11617), VDD = 5V (MAX11612/MAX11614/MAX11616), fSCL = 1.7MHz, (50% duty cycle),
fSAMPLE = 94.4ksps, single-ended, unipolar, TA = +25°C, unless otherwise noted.)
DIFFERENTIAL NONLINEARITY
vs. DIGITAL CODE
0.5
0.4
0.3
0.2
0.1
0
0.1
-0.2
-0.3
-0.4
-0.5
0
500 1000 1500 2000 2500 3000 3500 4000
DIGITAL OUTPUT CODE
INTEGRAL NONLINEARITY
vs. DIGITAL CODE
1.0
0.8
0.6
0.4
0.2
0
-0.2
-0.4
-0.6
-0.8
-1.0
0 500 1000 1500 2000 2500 3000 3500 4000
DIGITAL OUTPUT CODE
FFT PLOT
-60
fSAMPLE = 94.4ksps
fIN = 10kHz
-80
-100
-120
-140
-160
-180
0
10k 20k 30k 40k 50k
FREQUENCY (Hz)
SUPPLY CURRENT
vs. TEMPERATURE
800
INTERNAL REFERENCE MAX11616/MAX11614/
750 MAX11612
700
SETUP BYTE
650
EXT REF: 10111011
INT REF: 11011011
600
550 INTERNAL REFERENCE MAX11617/MAX11615/
500 MAX11613
450 EXTERNAL REFERENCE MAX11616/MAX11614/
MAX11612
400
350 EXTERNAL REFERENCE MAX11617/MAX11615/
MAX11613
300
-40 -25 -10 5 20 35 50 65 80
TEMPERATURE (°C)
SHUTDOWN SUPPLY CURRENT
vs. SUPPLY VOLTAGE
0.6
SDA = SCL = VDD
0.5
0.4
0.3
0.2
0.1
0
2.7 3.2 3.7 4.2 4.7 5.2
SUPPLY VOLTAGE (V)
SHUTDOWN SUPPLY CURRENT
vs. TEMPERATURE
0.50
0.45
MAX11616/MAX11614/MAX11612
0.40
0.35
0.30
0.25
MAX11617/MAX11615/MAX11613
0.20
0.15
0.10
0.05
0
-40 -25 -10 5 20 35 50 65 80
TEMPERATURE (°C)
6 _______________________________________________________________________________________