DS1339A
Low-Current, I2C, Serial Real-Time Clock
DC ELECTRICAL CHARACTERISTICS (continued)
(VCC = MIN to MAX, VBACKUP = MIN to MAX, TA = -40NC to +85NC, unless otherwise noted.) (Note 2)
PARAMETER
SYMBOL
CONDITIONS
MIN
Trickle-Charger Resistor Register
10h = A6h, VCC = Typ,
R2
VBACKUP = 0V
Trickle-Charger Resistor Register
10h = A7h, VCC = Typ,
VBACKUP = 0V
VBACKUP Leakage Current
R3
IBKLKG
-100
TYP
2000
4000
25
MAX
200
UNITS
I
I
nA
DC ELECTRICAL CHARACTERISTICS
(VCC = 0V, VBACKUP = MIN to MAX, TA = -40NC to +85NC, unless otherwise noted.) (Note 2)
PARAMETER
SYMBOL
CONDITIONS
MIN TYP MAX UNITS
VBACKUP Current EOSC = 0,
SQW Off
IBKOSC (Note 8)
300 600
nA
VBACKUP Current EOSC = 0,
SQW On
IBKSQW (Note 8)
500 1100
nA
VBACKUP Current EOSC = 1
IBKDR
10
200
nA
AC ELECTRICAL CHARACTERISTICS
(VCC = MIN to MAX, TA = -40NC to +85NC, unless otherwise noted.) (Note 2, Figure 1)
PARAMETER
SYMBOL
CONDITIONS
SCL Clock Frequency
Bus Free Time Between a STOP
and START Condition
fSCL
tBUF
Hold Time (Repeated) START
Condition
tHD:STA (Note 9)
Low Period of SCL Clock
High Period of SCL Clock
Setup Time for a Repeated
START Condition
tLOW
tHIGH
tSU:STA
Data Hold Time
Data Setup Time
Rise Time of Both SDA and SCL
Signals
tHD:DAT
tSU:DAT
tR
(Notes 10, 11)
(Note 12)
(Note 13)
Fall Time of Both SDA and SCL
Signals
tF
(Note 13)
Setup Time for STOP Condition
tSU:STO
MIN TYP MAX UNITS
0.03
400
kHz
1.3
Fs
0.6
1.3
0.6
0.6
0
100
20 +
0.1CB
20 +
0.1CB
0.6
Fs
Fs
Fs
Fs
0.9
Fs
ns
300
ns
300
ns
Fs
  3