MAX16047 Datasheet, PDF (24/62 Pages) Maxim Integrated Products – 12-Channel/8-Channel EEPROM-Programmable System Managers with Nonvolatile Fault Registers
12-Channel/8-Channel EEPROM-Programmable
System Managers with Nonvolatile Fault Registers
Table 8. EN_OUT1–EN_OUT12 Configuration
REGISTER/
EEPROM
ADDRESS
BIT RANGE
DESCRIPTION
[2:0]
EN_OUT1 Configuration:
000 = EN_OUT1 is an open-drain active-low output
001 = EN_OUT1 is an open-drain active-high output
010 = EN_OUT1 is a push-pull active-low output
011 = EN_OUT1 is a push-pull active-high output
100 = EN_OUT1 is used in closed-loop tracking
101 = EN_OUT1 is configured with a charge-pump output (MON1 + 5V) capable of driving an
external n-channel MOSFET
110 = Reserved
111 = Reserved
EN_OUT2 Configuration:
000 = EN_OUT2 is an open-drain active-low output
001 = EN_OUT2 is an open-drain active-high output
010 = EN_OUT2 is a push-pull active-low output
1Fh
[5:3]
011 = EN_OUT2 is a push-pull active-high output
100 = EN_OUT2 is used in closed-loop tracking
101 = EN_OUT2 is configured with a charge-pump output (MON2 + 5V) capable of driving an
external n-channel MOSFET
110 = Reserved
111 = Reserved
[7:6]
EN_OUT3 Configuration (LSBs):
000 = EN_OUT3 is an open-drain active-low output
001 = EN_OUT3 is an open-drain active-high output
010 = EN_OUT3 is a push-pull active-low output
011 = EN_OUT3 is a push-pull active-high output
100 = EN_OUT3 is used in closed-loop tracking
101 = EN_OUT3 is configured with a charge-pump output (MON3 + 5V) capable of driving an
external n-channel MOSFET
110 = Reserved
111 = Reserved
24 ______________________________________________________________________________________