MAX16068 Datasheet, PDF (20/40 Pages) Maxim Integrated Products – 6-Channel, Flash-Configurable System Manager with Nonvolatile Fault Registers
6-Channel, Flash-Configurable System Manager
with Nonvolatile Fault Registers
Table 15. Reset Output Configuration
REGISTER
ADDRESS
FLASH
ADDRESS
BIT RANGE
DESCRIPTION
RESET Soft Trigger
[0]
0 = Normal RESET behavior
1 = Force RESET to assert
[1]
Not used
[2]
0 = Active low
1 = Active high
[3]
0 = Open drain
1 = Push-pull
Reset Timeout Period
0000 = 25Fs
0001 = 1.5ms
3Bh
23Bh
0010 = 2.5ms
0011 = 4ms
0100 = 6ms
0101 = 10ms
0110 = 15ms
[7:4]
0111 = 25ms
1000 = 40ms
1001 = 60ms
1010 = 100ms
1011 = 150ms
1100 = 250ms
1101 = 400ms
1110 = 600ms
1111 = 1s
[0]
1 = RESET depends on MON1 undervoltage
[1]
1 = RESET depends on MON2 undervoltage
[2]
1 = RESET depends on MON3 undervoltage
3Ch
23Ch
[3]
1 = RESET depends on MON4 undervoltage
[4]
1 = RESET depends on MON5 undervoltage
[5]
1 = RESET depends on MON6 undervoltage
[7:6]
Not used
[0]
1 = RESET depends on MON1 overvoltage
[1]
1 = RESET depends on MON2 overvoltage
[2]
1 = RESET depends on MON3 overvoltage
3Dh
23Dh
[3]
1 = RESET depends on MON4 overvoltage
[4]
1 = RESET depends on MON5 overvoltage
[5]
1 = RESET depends on MON6 overvoltage
[7:6]
Not used