English
Language : 

MAX16068 Datasheet, PDF (12/40 Pages) Maxim Integrated Products – 6-Channel, Flash-Configurable System Manager with Nonvolatile Fault Registers
6-Channel, Flash-Configurable System Manager
with Nonvolatile Fault Registers
Table 3. ADC Configuration Registers
REGISTER ADDRESS
43h
44h
FLASH ADDRESS
243h
244h
BIT RANGE
[1:0]
[3:2]
[5:4]
[7:6]
[1:0]
[3:2]
[7:4]
DESCRIPTION
MON1 Full-Scale Range
00 = 5.6V
01 = 2.8V
10 = 1.4V
11 = channel not converted
MON2 Full-Scale Range
00 = 5.6V
01 = 2.8V
10 = 1.4V
11 = channel not converted
MON3 Full-Scale Range
00 = 5.6V
01 = 2.8V
10 = 1.4V
11 = channel not converted
MON4 Full-Scale Range
00 = 5.6V
01 = 2.8V
10 = 1.4V
11 = channel not converted
MON5 Full-Scale Range
00 = 5.6V
01 = 2.8V
10 = 1.4V
11 = channel not converted
MON6 Full-Scale Range
00 = 5.6V
01 = 2.8V
10 = 1.4V
11 = channel not converted
Not used
Boot-Up Delay
Once EN is above its threshold and the software enable
bit is set, a boot-up delay occurs before monitoring
begins. This delay is configured in register 77h as shown
in Table 4, and it is stored as an 8-bit value calculated
as follows:
tBOOT = (5 x 10-6) x 2a x (16 + b) + 480µs
where tBOOT is in seconds, a is the decimal value of the
4 MSBs and b is the decimal value of the 4 LSBs.
Table 4. Boot-Up Delay
REGISTER
ADDRESS
77h
FLASH
ADDRESS
277h
BIT
RANGE
[7:0]
Boot-up delay
DESCRIPTION
12   �������������������������������������������������������������������������������������