12.4 BERT
12.4.1 BERT Register Map
The BERT utilizes twelve registers.
Table 12-13. BERT Register Map
Address
060h
062h
064h
066h
068h
06Ah
06Ch
06Eh
070h
072h
074h
076h
078h
07Ah
07Ch
07Eh
Register
BERT.CR
BERT.PCR
BERT.SPR1
BERT.SPR2
BERT.TEICR
--
BERT.SR
BERT.SRL
BERT.SRIE
--
BERT.RBECR1
BERT.RBECR2
BERT.RBCR1
BERT.RBCR2
--
--
Register Description
BERT Control Register
BERT Pattern Configuration Register
BERT Seed/Pattern Register #1
BERT Seed/Pattern Register #2
BERT Transmit Error Insertion Control Register
Unused
BERT Status Register
BERT Status Register Latched
BERT Status Register Interrupt Enable
Unused
BERT Receive Bit Error Count Register #1
BERT Receive Bit Error Count Register #2
BERT Receive Bit Count Register #1
BERT Receive Bit Count Register #2
Unused
Unused
12.4.2 BERT Register Bit Descriptions
Register Name:
Register Description:
Register Address:
Bit #
15
Name
--
Default
0
Bit #
Name
Default
7
PMUM
0
BERT.CR
BERT Control Register
060h
14
13
12
--
--
--
0
0
0
6
LPMU
0
5
RNPL
0
4
RPIC
0
11
--
0
3
MPR
0
10
--
0
2
APRD
0
9
--
0
1
TNPL
0
8
--
0
0
TPIC
0
Bit 7: Performance Monitoring Update Mode (PMUM) – When 0, a performance monitoring update is initiated by
the LPMU register bit. When 1, a performance monitoring update is initiated by the global or port PMU register bit.
Note: If the LPMU bit or the global or port PMU bit is one, changing the state of this bit may cause a performance
monitoring update to occur.
Bit 6: Local Performance Monitoring Update (LPMU) – This bit causes a performance monitoring update to be
initiated if local performance monitoring update is enabled (PMUM = 0). A 0 to 1 transition causes the performance
monitoring registers to be updated with the latest data, and the counters reset (0 or 1). For a second performance
monitoring update to be initiated, this bit must be set to 0, and back to 1. If LPMU goes low before the PMS bit
goes high; an update might not be performed. This bit has no affect when PMUM=1.
Bit 5: Receive New Pattern Load (RNPL) – A zero to one transition of this bit will cause the programmed test
pattern (QRSS, PTS, PLF[4:0}, PTF[4:0], and BSP[31:0]) to be loaded in to the receive pattern generator. This bit
144 of 230