English
Language : 

MAX1272 Datasheet, PDF (12/20 Pages) Maxim Integrated Products – Fault-Protected, 12-Bit ADCs with Software-Selectable Input Range
Fault-Protected, 12-Bit ADCs
with Software-Selectable Input Range
CS
DIN
HI-Z
DOUT
SCLK
CONTROL BYTE 0
MSB
CONTROL BYTE 1
RESULT 0
LSB
MSB
CONTROL BYTE 2
RESULT 1
LSB
ACQUISITION
4 SCLKs
CONVERSION
12 SCLKs
ACQUISITION
4 SCLKs
CONVERSION
12 SCLKs
Figure 6. Conversion Timing, 16 Clocks/Conversion
Starting a Conversion
The MAX1272/MAX1273 use the serial clock to complete
an acquisition. The falling edge of CS does not start a
conversion on the MAX1272/MAX1273. Each conversion
requires a control byte. Programming the fourth bit in the
control byte starts the acquisition sequence. Conversion
starts on the falling edge of the eighth clock cycle after
the start bit.
Keep CS low during successive conversions. If a start bit
is received after CS transitions from high to low, but before
the output bit 4 (D4) becomes available, the current con-
version terminates and a new conversion begins. DOUT
enters high-impedance state when CS transitions high.
SCLK shifts data in and out of the MAX1272/MAX1273
and controls both acquisition and conversion timing.
Conversion begins immediately after the end of the
acquisition cycle. Successive-approximation bit deci-
sions appear at DOUT on each of the following 12 clock
falling edges (Figure 5). Additional clock falling edges
result in trailing zeros at DOUT.
The maximum running rate of the MAX1272/MAX1273 is
16 clocks per conversion. A clock speed of 1.4MHz
allows for a maximum sampling rate of 87ksps (Figure 6).
To achieve the maximum throughput, keep CS low, and
start the control byte after bit 4 (D4) of the conversion in
progress clocks out on DOUT.
If CS is low and SCLK is continuous, guarantee a start
bit by first clocking in 16 zeros.
Applications Information
Power-On Reset
The MAX1272/MAX1273 power-up in normal operating
mode (all internal circuitry active), and external reference
mode. The MAX1272/MAX1273 require a start bit to initi-
ate a conversion. The contents of the output data register
clear during power-up.
Internal or External Reference
Operate the MAX1272/MAX1273 with an internal or an
external reference. Configure REF as an internal refer-
ence output or an external reference input using the
serial interface. When changing from external reference
mode to internal reference mode, allow 2ms (CREF =
1µF) for the reference to stabilize before taking any
measurement.
Internal Reference
The internally trimmed reference provides 4.096V at REF.
Bypass REF to GND with a 1.0µF capacitor (Figure 7a).
12 ______________________________________________________________________________________