English
Language : 

MAX11208 Datasheet, PDF (12/14 Pages) Maxim Integrated Products – 20-Bit, Single-Channel, Ultra-Low-Power, Delta-Sigma ADC with 2-Wire Serial Interface
20-Bit, Single-Channel, Ultra-Low-Power,
Delta-Sigma ADC with 2-Wire Serial Interface
SCLK
RDY/DOUT
CONVERSION IS DONE
DATA IS AVAILABLE
1
2
3
t9
t10
D19
D18
DEVICE ENTERS
SLEEP MODE
DEVICE EXITS OUT
SLEEP MODE
24
SLEEP
MODE
1
2
0
D19
D18
CONVERSION IS DONE
DATA IS AVAILABLE
t11
Figure 4. Timing Diagram for Data Read Followed by Sleep-Mode Activation; Single Conversion Timing
SCLK
RDY/DOUT
CONVERSION IS DONE
DATA IS AVAILABLE
25TH SCLK PULLS RDY/DOUT HIGH
DEVICE ENTERS
SLEEP MODE
DEVICE EXITS OUT SLEEP MODE
AND STARTS CALIBRATION
1
2
3
t10
24
25
26
SLEEP
MODE
1
2
D19
D18
0
D19 D18
CONVERSION IS DONE
DATA IS AVAILABLE AFTER CALIBRATION
t12
Figure 5. Timing Diagram for Sleep-Mode Activation Followed by Self-Calibration at Wake-Up
12   �������������������������������������������������������������������������������������