3.6 Specifications
3.6.1 Functional (continued)
Process Conditions
Maximum process temperature Œ
Maximum process pressure Œ
Minimum process pressure Œ
Environment
Operating temperature
Display function operating temperature
Storage temperature
Humidity
Electromagnetic compatibility
Installation
Orientation
+1000° F @ 500 psig (+538° C @ 35 bar)
5000 psig from -500° to +100° F (345 bar from -296° to +38° C)
-85° F (-65° C)
-40 to +175° F (-40 to +80° C)
-5 to +160° F (-20 to +70° C)
-40 to +175° F (-40 to +80° C)
0–99%, non-condensing
Meets CE Requirements (EN 50081-2, EN 50082-2)
Vertical, top-mounted
ΠDepends on probe selection.
See bulletin 50-125 for specifications of available probes.
3.6.2 Performance
Reference conditions
Accuracy
Resolution
Repeatability
Linearity
Hysteresis
Response time
Warm up time
Temperature effect
+20° C (+68° F)
±0.5% of span or 0.1" (whichever is greater)
0.1 pF
±0.1% of span
±0.25% of span
±0.1% of span
< 1 s (adjustable via damping)
<5s
Approximately +0.03%/° C
50-660 Kotron Model 805 Smart RF Level Transmitter
26