English
Language : 

F10-1D22-BKK Datasheet, PDF (17/28 Pages) Magnetrol International, Inc. – Flow Switches
4.4 Specifications
4.4.1 Model F10 Actuating Flow Rates (cont.)
Water Service m3/h
Model F10 units may be adjusted in service to actuate within the
minimum and maximum flow rates given below. A specific
gravity correction factor is applied for liquids other than water
(1.00 specific gravity).
Pipe Line Size Œ
Inches
2
21⁄2
3
31⁄2
4
5
6
8
10
12
14
16
18
20
22
24
26
28
30
Flow Increase (m3/h)
Minimum
Maximum 
4.8
14.3
5.2
16.8
7.3
20.0
8.6
22.7
10.2
27.2
13.8
34.1
17.9
40.9
27.2
52.2
38.6
70.4
52.2
86.3
61.3
97.6
77.2
115.8
97.6
133.8
118.0
156.6
140.7
177.1
165.7
204.3
193.0
233.8
222.5
263.3
252.0
292.8
Flow Decrease (m3/h)
Minimum
Maximum
3.6
10.9
4.5
12.7
5.4
14.8
6.4
17.0
7.5
19.3
9.8
25.0
12.5
29.5
18.6
36.3
25.0
47.7
34.1
56.8
38.6
63.6
49.9
72.6
61.3
84.0
72.6
97.6
86.3
109.0
102.2
124.9
118.0
140.7
133.9
158.9
152.1
177.1
ΠBased upon Sch 40 pipe.
 For higher flow rates consult factory.
47-602 F10 and F50 Flow Switches
17