4.4 Specifications
4.4.1 Model F10 Actuating Flow Rates
Water Service GPM
Model F10 units may be adjusted in service to actuate within the
minimum and maximum flow rates given below. A specific
gravity correction factor is applied for liquids other than water
(1.00 specific gravity). A vane length equal to the line size of the
horizontal pipe is required.
Pipe Line Size Œ
Inches
2
21⁄2
3
31⁄2
4
5
6
8
10
12
14
16
18
20
22
24
26
28
30
Flow Increase (GPM)
Minimum
Maximum 
21
63
26
74
32
88
38
100
45
120
61
150
79
180
120
230
170
310
230
380
270
430
340
510
430
590
520
690
620
780
730
900
850
1030
980
1160
1110
1290
ΠBased upon Sch 40 pipe.
 For higher flow rates consult factory.
Flow Decrease (GPM)
Minimum
Maximum
16
48
20
56
24
65
28
75
33
85
43
110
55
130
82
160
110
210
150
250
170
280
220
320
270
370
320
430
380
480
450
550
520
620
590
700
670
780
16
47-602 F10 and F50 Flow Switches