1-207303-3 Datasheet, PDF (6/51 Pages) Tyco Electronics – AMP Circular Connectors for Commercial Signal & Power Applications
AMP Circular Connectors for
Note: All part numbers
Commercial Signal and Power Applications are RoHS Compliant.
Performance Characteristics — CPC and Metal-Shell CPC Connectors
More information on the
performance of AMP CPC
and metal-shell CPC
connectors is available by
requesting the following
AMP Product Specifications:
108-10024––
CPC Connectors
108-10037––
Type XII Contacts
108-10020––
Size 20 DM and 20 DF
Contacts
108-10040––
Metal-Shell CPC
Connectors
108-10042––
Type III+ Contacts
108-1579––
Sealed CPC Connectors
with Removeable Contacts
Test Description
Procedure
Maintenance
Aging
Contacts removed and
reinserted 10 times using
applicable tools
Contact Retention
Axial load applied to
contact to displace to the
rear of the connector
Dielectric Withstanding
Voltage (MIL-STD-1344,
Method 3001)
Connectors subjected to
1500 volts rms at sea
level
Thermal Shock
Connectors subjected to
five cycles of temperature
change (-55°C and +125°C)
Vibration
(MIL-STD-202,
Method 204,
Test Condition B)
Connectors vibrated
(wired and mated).
Contacts wired in series
with 100 milliamperes
flowing during the test
Physical Shock
(MIL-STD-202,
Method 213A,
Test Condition A)
Connectors shocked
50 G (wired and mated).
Contacts wired in series
with 100 milliamperes
flowing during the test
Durability
Connectors mated and
unmated 25 times with tin
plated contacts and 500
times with gold plated
contacts
Corrosion (Salt Spray)
(MIL-STD-202, Method 101,
Test Condition B)
Mated connectors
subjected to 5% salt
spray for 48 hours
Protection Against
Solids
Protection Against
Water
a. Test wire is pushed
into mated connectors
b. Mated connectors
subjected to circulating
talcum powder
Water is projected through
jets against mated
connector from any direction
and then temporarily
immersed in water
Temperature Life
Mated connectors
subjected to a temperature
of +125°C for 200 hours
Insulation Resistance
(MIL-STD-1344,
Method 3003)
Measurement made
between adjacent contacts
with connector mated
Humidity
(MIL-STD-202, Method 103,
Test Condition B)
Mated connectors
subjected to 10 days
moisture test
*For size 16 contacts. Size 8 contacts 25 lb. load, min.
Requirements
No damage to contacts
or housings. Contact
retention maintained
Contacts remain in
place when subjected to
a minimum 10 lb. load*
No breakdown or
flashover
No damage
No damage or loosening of
parts. No interruption
of electrical continuity
longer than 10 microseconds
No damage or loosening
of parts. No interruption of
electrical continuity longer
than 10 microseconds
No wear through
damage to plating
No damage
a. Must not touch live parts
b. No dust deposits
observed on mating
surfaces
No water deposits shall
be observed on mating
surfaces of contacts
or housings
No damage
5000 megohms
minimum ambient
temperature
Minimum insulation
resistance of
100 megohms
6
Catalog 82021
Revised 7-07
www.tycoelectronics.com
Dimensions are in inches and
millimeters unless otherwise
specified. Values in brackets
are metric equivalents.
Dimensions are shown for
reference purposes only.
Specifications subject
to change.