8.4. Air Valve Spool Adjustment
A. Crimp Function
If the jaws close too slowly or not at all the control button is fully depressed, perform the following:
1. Make sure that the air pressure is regulated at 552 kPa [80 psi] minimum to 689 kpa [100 psi]
maximum.
2. With the control button fully depressed, insert the tip of a screw driver through the rear exhaust port
and into the slot at the rear of the air valve spool. See Figure 10.
3. Turn the screw driver COUNTER–CLOCKWISE until the jaws are fully closed. Stop turning the screw
driver as soon as the jaws are closed and when there is no evidence of air escaping through the exhaust
ports.
4. Cycle the tool a few times to ensure that the tool is functioning properly.
B. Cam Return Function
If jaws open too slowly or not at all when the control button is released, perform the following:
1. Make sure that the air pressure is regulated at 552 kPa [80 psi] minimum to 689 kpa [100 psi]
maximum.
2. With the control button fully depressed, insert the tip of a screw driver through the rear exhaust port
and into the slot at the rear of the air valve spool. See Figure 10.
3. Turn the screw driver CLOCKWISE until the jaws are fully open. Stop turning the screw driver as
soon as the jaws are open and when there is no evidence of air escaping through the exhaust ports.
4. Cycle the tool a few times to ensure that the tool is functioning properly.
9. REVISION SUMMARY
Revisions to this customer manual include:
S Updated document to corporate requirements
S Removed obsolete Tool 68068–4
S Removed obsolete jaw assemblies and added instruction sheet referenced to Figure 5
S Added jaw position to Figure 6
S Removed obsolete items or items related to obsolete tool from Figure 9
S Added Paragraph 2.1
S Changed “rear plug” to “piston” in Paragraph 8.1, Step 12 and Paragraph 8.2, Step 18
S Added lubrication symbol to jaw cam rollers in Figure 7
S Added ordering parts information and changed customer repair service information in Section 8