English
Language : 

28236-DSH-001-B Datasheet, PDF (396/443 Pages) M/A-COM Technology Solutions, Inc. – ATM ServiceSAR Plus with xBR Traffic Management
16.0 Electrical and Mechanical Specifications
16.3 DC Characteristics
CN8236
ATM ServiceSAR Plus with xBR Traffic Management
16.3 DC Characteristics
The DC electrical characteristics are listed in Table 16-12.
Table 16-12. DC Characteristics (1 of 2)
Parameter
Conditions
Operating Supply Voltage (Vdd)
Output Voltage High
Output Voltage Low
Input Voltage High
(PCI)
Input Voltage High
(CLK2X, RxClk, TxClk)
Input Voltage High
(all others)
Input Voltage Low
(PCI)
Input Voltage Low
(CLK2X, RxClk, TxClk)
Input Voltage Low
(all others)
Input Leakage Current
—
IOH = –500 µA
(for all 3.3 V PCI signaling)
IOH = –2 mA
(for all 5 V PCI signaling)
IOH = 4.0 mA
(for all other signals)
IOL = 1500 µA
(for all 3.3 V PCI signals)
IOH = 3 mA, 6 mA (1)
(for all 5 V PCI signaling)
IOL = 4.0 mA
(for all other signals)
(for 3.3 V PCI signaling)
(for 5 V PCI signaling)
—
—
(for 3.3 V PCI signaling)
(for 5 V PCI signaling)
—
—
Vin = Vdd or GND
Min
3.0
0.9*Vdd
2.4
2.4
—
—
—
0.5*Vdd
2.0
0.7*Vdd
2.0
–0.5
–0.5
0
0
–10
Max
3.6
—
—
—
0.1*Vdd
0.55
0.4
5.25
5.25
5.25
5.25
0.3*Vdd
0.8
0.3*Vdd
0.8
10
Unit
V
V
V
V
V
V
V
V
V
V
V
V
V
V
V
µA
16-20
Mindspeed Technologies™
28236-DSH-001-B