English
Language : 

L130-2780002011001 Datasheet, PDF (4/24 Pages) Lumileds Lighting Company – Hot targeted leading lm/$ QFN with superior lumen maintenance
Product Selection
Product Selection Guide for LUXEON 3020 LEDs
Junction Temperature = 25°C
Table 1.
Nominal
CCT
Part Number
Luminous Flux (lm) [1]
@ 120 mA, 25°C
Minimum
Typical
2700K
L130-2780002011001
39.0
44.5
3000K
L130-3080002011001
40.0
46.0
3500K
L130-3580002011001
41.0
46.5
4000K
5000K
L130-4080002011001
L130-5080002011001
43.0
43.0
48.5
49.0
5700K
L130-5780002011001
43.0
49.0
6500K
L130-6580002011001
43.0
48.5
Notes for Table 1:
1. Philips Lumileds maintains a tolerance of ± 7.5% on luminous flux, ± 2 on CRI.
2. Calculated and interpolated values.
3. Typical thermal resistance is measured from junction to solder pads.
Luminous Flux (lm) [2]
@ 100 mA, 25°C
Minimum
Typical
33.5
37.0
34.5
38.0
35.0
38.5
37.0
40.0
37.0
40.5
37.0
40.5
37.0
40.0
Electrical Characteristics
CRI [1]
Minimum
Rth_J_c
(°C/W)[3]
Typical
80
13
Electrical Characteristics
Thermal Pad Temperature = 25°C, Test Current @ 120 mA
Table 2.
Part Number
Forward Voltage Vf [1] (V)
Minimum
Typical
Maximum
Temperature Coefficient of
Forward Voltage between 25°C and 85°C
DVF / DTJ
L130-2780002011001
L130-3080002011001
L130-3580002011001
L130-4080002011001
2.85
3.05
L130-5080002011001
L130-5780002011001
L130-6580002011001
Notes for Table 2:
1. Philips Lumileds maintains a tolerance of ± 0.1V on forward voltage measurements.
2. Measured between T = 25°C and T = 85°C.
j
j
3.30
-2.0 to -4.0
LUXEON 3020 Datasheet DS209 20140320 ©2014 Philips Lumileds Lighting Company.
3