English
Language : 

L130-2780002011001 Datasheet, PDF (3/24 Pages) Lumileds Lighting Company – Hot targeted leading lm/$ QFN with superior lumen maintenance
General Information
Product Nomenclature
LUXEON 3020 is tested and binned at T = 25°C and 120 mA DC.
j
The part number designation is explained as follow:
L130-AABB002011001
Where:
AA — designates CCT (2700 = 27, 3000 = 30, 3500 = 35, 4000 = 40, 5000 = 50, 5700 = 57, 6500 = 65)
BB — designates CRI (70, 80 and 90)
Therefore the part number for a 4000K, 80 CRI, LUXEON 3020 product will be:
L130–4080002011001
Average Lumen Maintenance Characteristics
Lumen maintenance for solid-state lighting devices (LEDs) is typically defined in terms of the percentage of initial
light output remaining after a specified period of time. Please visit the following website for detailed operating
conditions:http://www.philipslumileds.com/support/documentation/lumen-maintenance. Or contact your local
Philips Lumileds Technical Solutions Manager for TM-21 extrapolations or other support. Observation of design limits
included in this data sheet is required in order to achieve this projected lumen maintenance.
Environmental Compliance
Philips Lumileds is committed to providing environmentally friendly products to the solid-state lighting market.
LUXEON 3020 is compliant to the European Union directives on the restriction of hazardous substances in electronic
equipment, namely the RoHS and REACH directives. Philips Lumileds will not intentionally add the following
restricted material to the LUXEON 3020 L130-xx80002011001: lead, mercury, cadmium, hexavalent chromium,
polybrominated biphenyls (PBB) or polybrominated diphenyl ethers (PBDE).
LUXEON 3020 Datasheet DS209 20140320 ©2014 Philips Lumileds Lighting Company.