English
Language : 

LTC3729_15 Datasheet, PDF (4/30 Pages) Linear Technology – 550kHz, PolyPhase, High Efficiency, Synchronous Step-Down Switching Regulator
LTC3729
ELECTRICAL CHARACTERISTICS The l denotes the specifications which apply over the full operating
temperature range, otherwise specifications are at TA = 25°C. VIN = 15V, VRUN/SS = 5V unless otherwise noted.
SYMBOL
IPLLFLTR
RRELPHS
CLKOUT
PARAMETER
Phase Detector Output Current
Sinking Capability
Sourcing Capability
Controller 2-Controller 1 Phase
Phase (Relative to Controller 1)
CLKHIGH
Clock High Output Voltage
CLKLOW
Clock Low Output Voltage
PGOOD Output
VPGL
IPGOOD
VPG
PGOOD Voltage Low
PGOOD Leakage Current
PGOOD Trip Level, Either Controller
Differential
Amplifier
ADA
CMRRDA
RIN
Gain
Common Mode Rejection Ratio
Input Resistance
CONDITIONS
fPLLIN < fOSC
fPLLIN > fOSC
VPHASMD = 0V, Open
VPHASMD = 5V
VPHASMD = 0V
VPHASMD = Open
VPHASMD = 5V
IPGOOD = 2mA
VPGOOD = 5V
VEAIN with Respect to Set Output Voltage
VEAIN Ramping Negative
VEAIN Ramping Positive
0V < VCM < 5V
Measured at VOS+ Input
MIN TYP MAX UNITS
–15
µA
15
µA
180
Deg
240
Deg
60
Deg
90
Deg
120
Deg
4
V
0.2
V
0.1
0.3
V
±1
µA
–6
–7.5 –9.5
%
6
7.5
9.5
%
0.995
1
1.005
V/V
46
55
dB
80
kΩ
Note 1: Absolute Maximum Ratings are those values beyond which
the life of a device may be impaired.
Note 2: TJ is calculated from the ambient temperature TA and power
dissipation PD according to the following formulas:
LTC3729EG: TJ = TA + (PD • 95°C/W)
LTC3729EUH: TJ = TA + (PD • 34°C/W)
Note 3: The LTC3729 is tested in a feedback loop that servos VITH to a
specified voltage and measures the resultant VEAIN.
Note 4: Dynamic supply current is higher due to the gate charge being
delivered at the switching frequency. See Applications Information.
Note 5: The minimum on-time condition corresponds to the on inductor
peak-to-peak ripple current ≥40% of IMAX (see Minimum On-Time
Considerations in the Applications Information section).
Note 6: The LTC3729E is guaranteed to meet performance specifications
from 0°C to 70°C. Specifications over the –40°C to 85°C operating
temperature range are assured by design, characterization and correlation
with statistical process controls.
3729fb
4