English
Language : 

LTC3868-1 Datasheet, PDF (15/38 Pages) Linear Technology – Low IQ, Dual 2-Phase Synchronous Step-Down Controller
LTC3868-1
Operation (Refer to the Functional Diagram)
proportional to IRMS2, meaning that the actual power wasted
is reduced by a factor of 2.66. The reduced input ripple
voltage also means less power is lost in the input power
path, which could include batteries, switches, trace/con-
nector resistances and protection circuitry. Improvements
in both conducted and radiated EMI also directly accrue as
a result of the reduced RMS input current and voltage.
Of course, the improvement afforded by 2-phase opera-
tion is a function of the dual switching regulator’s relative
duty cycles which, in turn, are dependent upon the input
voltage VIN (Duty Cycle = VOUT/VIN). Figure 3 shows how
the RMS input current varies for single-phase and 2-phase
operation for 3.3V and 5V regulators over a wide input
voltage range.
It can readily be seen that the advantages of 2-phase op-
eration are not just limited to a narrow operating range,
for most applications is that 2-phase operation will reduce
the input capacitor requirement to that for just one channel
operating at maximum current and 50% duty cycle.
3.0
SINGLE PHASE
2.5
DUAL CONTROLLER
2.0
1.5
2-PHASE
DUAL CONTROLLER
1.0
0.5 VO1 = 5V/3A
VO2 = 3.3V/3A
0
0
10
20
30
INPUT VOLTAGE (V)
40
38681 F03
Figure 3. RMS Input Current Comparison
38681fb
15