OPERATION (Refer to Functional Diagram)
While this is an impressive reduction in itself, remember
that the power losses are proportional to I2RMS, meaning
that the actual power wasted is reduced by a factor of
2.66. The reduced input ripple current also means that
less power is lost in the input power path, which could
include batteries, switches, trace/connector resistances
and protection circuitry. Improvements in both conducted
and radiated EMI also directly accrue as a result of the
reduced RMS input current and voltage.
Of course, the improvement afforded by 2-phase opera-
tion is a function of the dual switching regulator’s relative
duty cycles which, in turn, are dependent upon the input
voltage, VIN. Figure 2 shows how the RMS input current
varies for single phase and 2-phase operation for 3.3V and
5V regulators over a wide input voltage range.
It can readily be seen that the advantages of 2-phase opera-
tion are not just limited to a narrow operating range, but in
fact extend over a wide region. A good rule of thumb for
most applications is that 2-phase operation will reduce the
input capacitance requirement to that for just one channel
operating at maximum current and 50% duty cycle.
3.0
SINGLE PHASE
2.5
DUAL CONTROLLER
2.0
1.5
2-PHASE
DUAL CONTROLLER
1.0
0.5
VO1 = 5V/3A
VO2 = 3.3V/3A
0
0
10
20
30
INPUT VOLTAGE (V)
40
3708 F02
Figure 2. RMS Input Current Comparison