PIM400 Series; ATCA Board Power Input Modules
-36 to -75 Vdc; 400W/10A
Data Sheet
Digital Interface Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions. See
Feature Descriptions for additional information.
Parameter
Conditions
Symbol
Min
Typ
Max
Unit
Digital Signal Interface Characteristics
Clock frequency range
Measurement Tolerance
Feed Voltage A/B (-48V_AF & -48V_BF)
Holdup Voltage (V_HLDP)
-48V_OUT current (-48V_IOUT)
Module Temperature (TEMP)
fCLK
% of Io,max
100
400
kHz
+/-3
%
+/-3
%
+/-3
%
+/-3
0C
General Specifications
Parameter
Calculated MTBF (PO=0.8PO, RATED, 48VIN, TA=40°C, Airflow=300LFM)
Telecordia Issue 2 Method 1 Case 3
Weight
Device
Min
All

Typ
Max
2,308,563
28.3 (1.0)

Unit
Hours
g (oz.)
June 20, 2013
©2013 General Electric Company. All rights reserved.