PIM400 Datasheet, PDF (1/20 Pages) Lineage Power Corporation – -36 to -75 Vdc; 400W/10A | |||
|
GE
Data Sheet
PIM400 Series; ATCA Board Power Input Modules
-36 to -75 Vdc; 400W/10A
Applications
ï§ ATCA Front Board / Blade
ï§ Central Office Telecom equipment
ï§ High availability server and storage applications
Options
ï§ Choice of short pin lengths
ï§ I2C Digital Interface
Features
ï§ -48V/10A Dual redundant input power distribution
ï§ 3.3Vdc/3.6A & 5.0Vdc/150mA of isolated Management Power
for IPM or other housekeeping functions
ï§ Independent holdup capacitor charging voltage; trimmable
from 50 to 95Vdc for optimal real estate
ï§ ORâing functionality, Inrush protection & hot swap capability
ï§ Integral EMI filter designed for the ATCA board to meet CISPR
Class B with minimal external filtering
ï§ Protection: Reverse polarity, under voltage, input transient
over voltage/current and temperature
ï§ I2C digital interface options
ï§ Isolated A/B Feed Loss /Open Fuse Alarm
ï§ High efficiency : 98%
ï§ -40 to 85ºC ambient temperature operation
ï§ Industry Standard Quarter brick size: 58.4 mm x 36.8 mm x
13.7 mm (2.3 in x 1.45 in x 0.54 in)
ï§ MTBF : 2,308,563 hours per TELCORDIA
ï§ ISO** 9001 & ISO 14001 certified manufacturing facilities
ï§ Compliant to RoHS II EU âDirective 2011/65/EUâ
ï§ UL* 60950-1, 2nd Ed. Recognized, CSAâ C22.2 No. 60950 1-07
Certified, and VDEâ¡ (EN60950-1, 2nd Ed.) Licensed
ï§ Meets the voltage and current requirements for ETSI 300-
132-2 and complies with and licensed for Basic insulation
rating per EN60950-1
ï§ 2250 Vdc Isolation tested in compliance with IEEE 802.3¤ PoE
standards
ï§ ISO**9001 and ISO 14001 certified manufacturing facilities
Description
The PIM400 series of Power Input Modules are designed to greatly simplify the task of implementing dual redundant, hot swap â
48Vdc power distribution with EMI filtering on an ATCA or other telecom boards. The PIM400 with optional I2C digital interface
capability, when used with a variety of GEâs series of Bus converters (BarracudaTM Series) /POLs (DLynxTM Series) provides for a
quick, simple and elegant power solution to a wide variety of demanding & intelligent power system architectures.
* UL is a registered trademark of Underwriters Laboratories, Inc.
â CSA is a registered trademark of Canadian Standards Association.
â¡ VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
** ISO is a registered trademark of the International Organization of Standards
¤ IEEE and 802 are registered trademarks of the Institute of Electrical and Electronics Engineers, Incorporated.
June 20, 2013