English
Language : 

JNCW016A0R Datasheet, PDF (3/15 Pages) Lineage Power Corporation – 36–75 Vdc Input; 28Vdc Output; 16Adc Output
GE
Data Sheet
JNCW016A0R Orca Series; DC-DC Converter Power Modules
36–75 Vdc Input; 28.0Vdc Output; 16Adc Output
Electrical Specifications (continued)
Parameter
Device
Symbol
Min
Typ
Max
Unit
Output Voltage Set-point
(VIN=VIN,nom, IO=IO, max, Tc =25°C)
Output Voltage Set-Point Total Tolerance
(Over all operating input voltage, resistive load, and temperature
conditions until end of life)
Output Regulation
Line (VIN=VIN, min to VIN, max)
Load (IO=IO, min to IO, max)
Temperature (Tc = -40ºC to +100ºC)
Output Ripple and Noise on nominal output
(VIN=VIN, nom and IO=IO, min to IO, max)
RMS (5Hz to 20MHz bandwidth)
Peak-to-Peak (5Hz to 20MHz bandwidth)
External Capacitance
Without the Tunable Loop1
With the Tunable Loop2
Output Power (Vo=28V to 35.2V)
Output Current
Output Current Limit Inception (Constant current until Vo<VtrimMIN ,
duration <4s)
Output Short Circuit Current (VO≤ 0.25Vdc)
Hiccup mode
Efficiency
VIN=VIN, nom, Tc=25°C IO=IO, max , VO= VO,set
Switching Frequency
Dynamic Load Response
(Io/t=1A/10s; Vin=Vin,nom; Tc=25°C; Tested with a 470 μF
aluminum and a 10 µF ceramic capacitor across the load.)
All
All
All
All
All
All
All
All,
except -T
-T
-T
All
All
All
All
All
VO, set
VO
CO
CO,
CO
PO,max
Io
IO, lim
IO, sc
η
fsw
27.5
28
28.5
Vdc
27.0

29.0
Vdc

0.1
0.2
%Vo,set

0.1
0.2
%Vo,set


0.02
%/°C

45
55
mVrms

80
200
mVpk-pk
440
6500
μF
440
470
μF
440
10,000
μF


450
W
0
16.0
Adc
17.5

21.0
Adc
60
Apk
5
Arms
93.0
93.5

%

175

kHz
Load Change from Io= 50% to 75% of Io,max: Peak Deviation
Settling Time (Vo<10% peak deviation)
All
Vpk
ts

1

%VO, set

1.0

ms
Load Change from Io= 25% to 50% of Io,max: Peak Deviation
Settling Time (Vo<10% peak deviation)
Vpk

1

%VO, set
ts

1.0

ms
(Io/t=2A/10s; Vin=Vin,nom; Tc=25°C; Tested with a 880 μF
aluminum and a 10 µF ceramic capacitor across the load.)
Load Change from Io= 0% to 75% of Io,max: Peak Deviation
Settling Time (Vo<10% peak deviation)
All
Vpk
ts

2

%VO, set

1.0

ms
Load Change from Io= 75% to 0% of Io,max: Peak Deviation
Settling Time (Vo<10% peak deviation)
Vpk

2

%VO, set
ts

1.0

ms
1 Use a minimum 2 x 220uF output capacitor. Recommended capacitor is Nichicon PM series, 220uF/35V. If the ambient temperature at module
startup is between 0OC and -10OC, use a minimum 3 x 220uF capacitors, and between -10OC and -20OC, use a minimum 4 x 220uF capacitors. For
startup below -20OC, use 440uF minimum polymer capacitors.
2 External capacitors may require using the new Tunable Loop feature to ensure that the module is stable as well as getting the best transient
response. See the Tunable Loop section for details.
Isolation Specifications
Parameter
Isolation Capacitance
Isolation Resistance
Symbol
Min
Ciso

Riso
10
Typ
Max
Unit
15

nF


MΩ
August 14, 2013
©2012 General Electric Company. All rights reserved.
Page 3