English
Language : 

JNCW016A0R Datasheet, PDF (11/15 Pages) Lineage Power Corporation – 36–75 Vdc Input; 28Vdc Output; 16Adc Output
GE
Data Sheet
JNCW016A0R Orca Series; DC-DC Converter Power Modules
36–75 Vdc Input; 28.0Vdc Output; 16Adc Output
Thermal Considerations (continued)
Figure 18. Case (TREF ) Temperature Measurement Location
(top view).
Thermal Derating
Thermal derating is presented for two different applications:
1) Figure 19, the JNCW016A0R module is thermally coupled
to a cold plate inside a sealed clamshell chassis, without any
internal air circulation; and 2) Figure 20 , 21 and 22, the
JNCW016A0R module is mounted in a traditional open
chassis or cards with forced air flow. In application 1, the
module is cooled entirely by conduction of heat from the
module primarily through the top surface to a cold plate,
with some conduction through the module’s pins to the
power layers in the system board. For application 2, the
module is cooled by heat removal into a forced airflow that
passes through the interior of the module and over the top
base plate and/or attached heatsink.
Ambient Temperature, TA (oC)
Figure 20. Derating Output Current vs. local Ambient
temperature and Airflow, No Heatsink, Vin=48V, airflow
from Vi(-) to Vi(+).
Ambient Temperature, TA (oC)
Figure 21. Derating Output Current vs. local Ambient
temperature and Airflow, 0.5” Heatsink, Vin=48V, airflow
from Vi(-) to Vi(+).
Cold plate (inside surface) temperature (ºC)
Figure 19. Output Power Derating for JNCW016A0R in
Conduction cooling (cold plate) applications; Ta <70ºC
adjacent to module; VIN = VIN,NOM
Ambient Temperature, TA (oC)
Figure 22. Derating Output Current vs. local Ambient
temperature and Airflow, 1.0” Heatsink, Vin=48V, airflow
from Vi(-) to Vi(+).
August 14, 2013
©2012 General Electric Company. All rights reserved.
Page 11