JNCW016A0R Datasheet, PDF (2/15 Pages) Lineage Power Corporation – 36–75 Vdc Input; 28Vdc Output; 16Adc Output
GE
Data Sheet
JNCW016A0R Orca Series; DC-DC Converter Power Modules
36–75 Vdc Input; 28.0Vdc Output; 16Adc Output
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are absolute stress ratings
only, functional operation of the device is not implied at these or any other conditions in excess of those given in the operations
sections of the data sheet. Exposure to absolute maximum ratings for extended periods can adversely affect the device reliability.
Parameter
Input Voltage
Continuous
Transient, operational (≤100 ms)
Operating Ambient Temperature
Operating Case Temperature
(See Thermal Considerations section, Figure 17)
Storage Temperature
I/O Isolation Voltage: Input to Case, Input to Output
Output to Case
Device
Symbol
Min
All
VIN
-0.3
All
VIN,trans
-0.3
All
Ta
-40
All
Tc
-40
All
Tstg
-55
All


All


Max
Unit
80
Vdc
100
Vdc
85
°C
100
°C
125
°C
1500
Vdc
500
Vdc
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature conditions.
Parameter
Operating Input Voltage
(see Figure 12 for VIN MIN when using trim-up feature)
Maximum Input Current
Device
Symbol
Min
Typ
Max
Unit
All
VIN
36
48
75
Vdc
(VIN=36V to 75V, IO=IO, max)
All
IIN,max
14.0
Adc
Inrush Transient
All
I2t
Input Reflected Ripple Current, peak-to-peak
(5Hz to 20MHz, 12μH source impedance; VIN=0V to 75V, IO= IOmax ;
All
see Figure 7)
Input Ripple Rejection (120Hz)
All
2
A2s
20
mAp-p
50
dB
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This power module can be used in a wide variety of applications, ranging from simple standalone operation to being an integrated
part of complex power architecture. To preserve maximum flexibility, internal fusing is not included. Always use an input line fuse,
to achieve maximum safety and system protection. The safety agencies require a time-delay or fast-acting fuse with a maximum
rating of 25 A in the ungrounded input connection (see Safety Considerations section). Based on the information provided in this
data sheet on inrush energy and maximum dc input current, the same type of fuse with a lower rating can be used. Refer to the
fuse manufacturer’s data sheet for further information.
August 14, 2013
©2012 General Electric Company. All rights reserved.