English
Language : 

HO60-P Datasheet, PDF (3/15 Pages) LEM – Current Transducer
Insulation coordination
Parameter
Rms voltage for AC insulation test 50/60 Hz/1 min
Impulse withstand voltage 1.2/50 µs
Partial discharge extinction rms voltage @ 10 pC
Clearance (pri. - sec.)
Creepage distance (pri. - sec.)
Clearance (pri. - sec.)
Case material
Comparative tracking index
Application example
Application example
HO 60 .. 250-P series
Symbol
Ud
ÛW
Ue
dCI
dCp
-
-
CTI
-
-
Unit
Value
Comment
kV
4.3
kV
8
V
> 1170
Busbar / Secondary + jumpers
mm
>8
Shortest distance through air
mm
>8
Shortest path along device body
mm
>8
When mounted on PCB with
recommended layout
-
V0 according to
UL 94
600
-
600 V
CAT III PD2
Reinforced insulation, non
uniform field according to
EN 50178, EN 61010
-
1000 V
CAT III PD2
Based insulation, non uniform
field according to
EN 50178, EN 61010
Application example
-
-
600 V
CAT III PD2
Simple insulation, non uniform
field according to UL 508
Environmental and mechanical characteristics
Parameter
Ambient operating temperature
Ambient storage temperature
Mass
Symbol
TA
TS
m
Unit
°C
°C
g
Min Typ Max
−40
105
−40
105
34
Comment
16July2015/Version 5
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice
Page 3/15
www.lem.com